sales hotline

CAST X Heaters

CASTX Family

The CAST-X 500 from CAS is a small, lightweight circulation heater ideal for heating gas or liquids in demanding applications. Even in its compact size, the CAST-X 500 is extremely powerful with operating temperatures up to 350°F (177°C) and working fluid pressure up to 3000psi. The CAST-X 500 heater is available in a variety of wattages and can be shipped in just a few days.

CAST-X 3000 IMPORTANT FEATURES

Applications

  • Solvent heating
  • Air, CO2 and nitrogen heating
  • DI water heating
  • Packaging sterilization
  • Hydrogen peroxide vaporization
  • Analytical instrumentation
  • Sample heating
  •  Food service
  •  Steam generation
  • Cleaning-in-place (CIP) systems
  • Pasteurization
  • Printing ink heating
  • Diesel and fuel heating

cast-x-500

CAST-X 500

  •  Power: •Up to 1500 W
  • Voltage Range: • 110 – 240
  • Max Line Current:•12.5 A
  • Tubing: •.250” OD (1/4″) (6.3 mm) .028” Wall (.7 mm)
  • Overall Process Tube
  • Length: •84” (2133 mm)
  • •316L Stainless Steel (standard)
  • Max Pressure: •3200 psi (220 bar)

Cast-X Circulation Heaters

CAST-X 1000

  •  Power: • 700 W Total to 3 kW Total
  • • Voltage Range: 120 – 480 V
  • • Max Line Current: 15 A
  • Tubing: • .313” OD (5/16″) (7.9 mm)
  • • 316L Stainless Steel (standard)
  • Max Pressure: •2100 psi (144 bar)
  • Max Working Temperatures: • No Enclosure: 662°F (350°C)
  • • NEMA 1 Enclosure and NEMA 4 Enclosure

CAST-X 2000 circulation heater

CAST-X 2000

  • Power: • 1 kW Total to 6 kW Total • Voltage Range: 120 – 480 V • Max Line Current: 25 A per circuit
  • Tubing: • .500” OD (1/2″) (12.7 mm) • .065” Wall (1.7 mm) • Overall Process Tube Length: 150” (3810 mm) • 316L Stainless Steel (standard)
  • Max Pressure: 4300 psi (295 bar)
  • Max Working Temperatures: • NEMA 1 (dust-proof/general-purpose): 482°F (250°C) with standoff: 662°F (350°C) with t-stat (w/ or w/o standoff: 250°F (121°C) • NEMA 4 (moisture-resistant): 350°F (175°C) with standoff: 662°F (350°C) • NEMA 7 (explosion-proof): 482°F (250°C)

CAST-X 2500

  •  •Power: • 2.5 kW Total to 15 kW Total • Voltage Range: 208 – 480V • Max Line Current: 30 A per circuit
  • Tubing: • .065” Wall (1.7 mm) • Overall Process Tube Length: 130” (3302 mm) each • 316L Stainless Steel (standard)
  • Max Pressure: 4000 psi (275 bar)
  • Max Working Temperatures:• NEMA 1 (dust-proof/general-purpose): 662°F (350°C) • NEMA 4 (moisture-resistant): 572°F (300°C) • NEMA 7 (explosion-proof): 482°F (250°C) • ATEX (explosion-proof): 4

CAST-X 3000 circulation heater

CAST-X 3000

  • Power: • 1 kW Total to 24.6 kW Total • Voltage Range: 208 – 480 V • Max Line Current: 35 A per circuit
  • Tubing: • .750” OD (3/4″) (19.1 mm) • .065” Wall (1.7 mm) • Overall Process Tube Length: 142” (3606 mm) each • 316L tainless Steel (standard)
  • Max Pressure: 3300 psi (227 bar)
  • Max Working Temperatures:• NEMA 4 (moisture-resistant): 572°F (300°C) • NEMA 7 / ATEX (explosion-proof): 482°F (250°C)

cast-x-4000 pic 2

CAST-X 4000

  • Power:• 12.5 kW Total to 60 kW Total • Voltage Range: 208 – 480 V • Max Line Current: 50 A per circuit
  • • Tubing:• 1.0” OD (25.4 mm) • .083” Wall (2.1 mm) • Overall Process Tube Length: 212” (5384 mm) each • 316L Stainless Steel (standard) • Inconel (optional upgrade) • Passivated or Electro-Polished (optional upgrades) •
  • Max Pressure2450 psi (169 bar) • Enclosures: • NEMA 4 • NEMA 7 / ATEX (explosion-proof) •
  • Max Working Temperatures: • NEMA 4 • NEMA 7 / ATEX (explosion-proof):  •
  • Sensors: • K or J Type Thermocouples Standard • RTD (resistance temperature detector)
  • Available Accessories: • Insulating Jackets • Compression Fittings